How to Read Trane Hvac Model Numbers
DANGER, WILL ROBINSON – READ FIRST
How to Replace a Trane Blower Motor is a multi-part series commodity, broken into Office 1 and Part 2.
Abstruse
Part I of the article serial contains data on identifying the blower motor problem, purchasing a replacement part, gathering necessary tools and finally disassembling the Trane Air Handler / Furnace for removal of the blower motor.
BACKGROUND
My Trane Ac / Key Heat has been solid since the installation appointment (dorsum in 1997 I believe). Of class with any mechanical setup, components wear out over a menses of time and that is exactly what happened when I started to hear loftier pitched sound (sort of similar metal-on-metal grinding noise) whenever the cooling / oestrus fan kicked in.
I researched information technology online afterwards looking inside my furnace / air handler and finding metallic shavings near the blower. I knew the motor was sealed (significant I could not periodically add oil to the begetting) and had been wondering about when it would neglect on me.
So I called my trusty HVAC place and asked a salesperson about a solution and he suggested that I supersede the blower motor. The replacement motor fabricated past Dayton was only $140 or then but the installation fee was fairly high at $340 and then I decided to tackle the job myself.
This detail salesperson was very professional and even gave me some tips (like making sure to salvage the motor mounting subclass equally it was very expensive to observe 1). He also recommended that I replace the capacitor at the same time as capacitors lose their efficiencies over fourth dimension. The cost for Dayton replacement capacitor was simply $8 actress then I bought 1 every bit recommended.
Item | Quondam | New |
Blower Motor | GE MotorsP01 924883007504 1400 1/3 HP, MOD 5KCP39JG P752 Due south Cp 5.00 / 370, RPM 1075/4SPD | Dayton 4M098G i/iii HP Cp 5.00 MFD / 370 VAC, RPM 1075 / 3SPD |
Capacitor | GE Z97F9239 5uF, 370 VAC 50/60 Hz A10000AFC 92-43Z572 D137452P03 | Dayton 5uF 370VAC fifty/60 Hz MPP2505370J 4506W E236128 |
REQUIRED TOOLS AND MATERIALS
- Replacement blower motor
- New capacitor
- Hammer
- Wire cutter / stripper
- Wire nuts
- Electric tape
- Mechanics Ratchet + sockets + extender
- Work glove
- Heavy duty safety gloves
- Digital camera
Stride-Past-Step REPLACEMENT GUIDE
- Turn off air conditioning / heat from the thermostat.
- Remove battery from the thermostat (or disconnect thermostat altogether).
- Turn off power at the main electric panel.
- Turn off the emergency HVAC shutoff switch
- Remove top and bottom encompass panels on the air handler / furnace unit (fig.5.1).
- Take detail pictures of where everything is located, including wiring setup from the motor, capacitor and controller (fig.v.2).
- WARNING – CAPACITOR Will BE HIGHLY CHARGED EVEN WHEN THE POWER IS TURNED OFF. DO NOT Cantankerous CONNECT OR Bear upon TERMINALS
- Remove top 2 metal screws property the door switch with 5/16" hex wrench (fig.5.3, fig.5.4).
- Remove bottom 2 metal screws holding the controller with 5/16" hex wrench
- Slide out the controller. Attached wires may be curt so you may need to rest it on a box of some sort adjacent to the air handler / furnace (fig.5.v).
- Have some other set of pictures, taking special note on how capacitor wires are attached (fig.5.6).
- Wearable a heavy duty rubber glove to remove the capacitor by start sliding off the rubber boot the disconnecting the wires (fig.five.7). Set up aside the old capacitor – you can either manually belch it or permit it sit effectually for awhile.
- Remove two screws belongings the fan shroud using a 3/8" socket (fig.v.8).
NEXT >> How to Supervene upon a Trane Blower Motor – Role two
RELATED POSTS
- How to Replace a Trane Blower Motor – Part 1
- How to Replace a Trane Blower Motor – Part ii
Reader Interactions
Trackbacks
Source: https://allthumbsdiy.com/hvac/how-to-replace-a-trane-blower-motor-part-1
0 Response to "How to Read Trane Hvac Model Numbers"
Post a Comment